1. DC Power Supply Module (Symmetrical ±15VDC) – TPAP.B0100
Origin: Vietnam
Technical Specifications
- Enclosure dimensions: 300 × 139 × 131 mm (L × W × H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 regarding power rating, current rating, leakage current, and dielectric strength
- Input power supply: 220VAC / 50Hz
- Output voltage: ±15VDC
- Rated output current: 3A
- Equipped with power indicator LEDs and fuse protection against overload and short circuit.
Main Components
- 01 Front panel
- 01 Plastic module enclosure (standard height: 300 mm)
- 01 Set of M4 safety terminals
- 01 Power supply circuit board
- 02 Switching power supplies
- 01 Fuse
- 01 Illuminated power switch
- 02 Power indicator LEDs
2. Reference Voltage Generation Module – TPAP.G0100
Origin: Vietnam
Technical Specifications
- Enclosure dimensions: 300 × 139 × 131 mm (L × W × H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 regarding power rating, current rating, leakage current, and dielectric strength
- Power supply: ±15VDC
- Output voltage:
- 0 to +10V, or
- –10 to +10V, selectable via switch
- Output voltage adjustable using a rotary knob
- Rated output current: 100mA
- Output voltage displayed on a 4-digit seven-segment LED display
- Resolution: 0.01V
Main Components
- 01 Front panel
- 01 Plastic enclosure
- 01 Set of M4 safety terminals
- 01 Potentiometer circuit board
- 01 Voltage generation circuit board
- 01 Display circuit board
- 01 Multi-turn potentiometer
- 01 Logic switch
- 01 Control knob
3. AC Voltmeter Training Module – TPAI.B0400
Origin: Vietnam
Technical Specifications
- Enclosure dimensions: 300 × 139 × 131 mm (L × W × H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 regarding power rating, current rating, leakage current, and dielectric strength
- Measurement range: 0–500VAC
- Display type: Analog pointer
- Scale deflection angle: 90°
Main Components
- 01 Front panel
- 01 Plastic enclosure
- 01 Set of M4 safety terminals
- 01 Analog AC voltmeter (500V)
4. Switching Training Module – TPAC.G0100
Technical Specifications
- Enclosure dimensions: 300 × 139 × 131 mm (L × W × H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 regarding power rating, current rating, leakage current, and dielectric strength
- Rotary switch positions: RS, ST, TR, RN, SN, TN, 0
- Input signal: Three-phase + Neutral (3P + N)
- Output signals: V1, V2 for voltmeter connection
- Contact rating: 10A / 220VAC
- Switching angle: 45°
Main Components
- 01 Front panel
- 01 Plastic enclosure
- 01 Set of M4 safety terminals
- 01 Voltmeter selector switch
5. AC Ammeter Training Module – TPAI.A0200
Origin: Vietnam
Technical Specifications
- Enclosure dimensions: 300 × 139 × 131 mm (L × W × H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 regarding power rating, current rating, leakage current, and dielectric strength
- Measurement range: 0–10AAC
- Display type: Analog pointer
- Scale deflection angle: 90°
- Short-circuit and overload protection
Main Components
- 01 Front panel
- 01 Plastic enclosure
- 01 Set of M4 safety terminals
- 01 Fuse
- 01 Analog AC ammeter (10A)
6. Three-Phase Resistive Load Training Module – TPAN.E3000
Technical Specifications
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 regarding power rating, current rating, leakage current, and dielectric strength
- Number of load branches: 3 (for three-phase operation), divided into 6 selectable steps
- Input voltage: 380VAC, 3-phase, 50Hz
- Resistance value: 100Ω
- Rated power: 1000W
- Integrated cooling fan
7. Inductive Load Training Module – TPAN.E3101
Technical Specifications
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 regarding power rating, current rating, leakage current, and dielectric strength
- Number of load branches: 3 (for three-phase operation), divided into 6 selectable steps
- Rated voltage (Y/Δ): 380/220VAC, 50Hz
- Rated current: 0.5–2A
8. Single-Phase IGBT Power Bridge Module – TPAP.E1200
Origin: Vietnam
Technical Specifications
- Enclosure dimensions: 300 × 272 × 130 mm (W × L × H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 regarding power rating, current rating, leakage current, and dielectric strength
- Input power supply: 220VAC / 50Hz
- DC input voltage: 20–300VDC
- Inverter output voltage: 20–300Vp
- Rated output current: 10A
- Control circuit: Optically isolated IGBT gate driver
- Control inputs: 2 digital inputs, 15Vp
- Test points: 4 outputs for IGBT gate terminals
- IGBT bridge rating: 40A / 600V
- Overcurrent and short-circuit protection
Main Components
- 01 Front panel
- 01 Plastic enclosure
- 01 Set of M4 safety terminals
- 01 IGBT bridge circuit board
- 01 Power supply circuit board
- 02 Fuses
- 01 Illuminated power switch
- 01 Transformer
9. Single-Phase PWM Inverter Control Module – TPAP.F0100
Origin: Vietnam
Technical Specifications
- Enclosure dimensions: 300 × 139 × 131 mm (L × W × H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 regarding power rating, current rating, leakage current, and dielectric strength
- Power supply: ±15VDC
Triangular Carrier Wave Generator
- Frequency ranges: 1kHz, 5kHz, 15kHz (switch selectable)
- Carrier amplitude: ±10Vp
Reference Sine Wave Generator
- Single-phase frequency: 0–100Hz
- Frequency control input: 0–10V
- Amplitude: ±10Vp
Signal Processing
- V/F ratio control
- SPWM generation by comparing the triangular carrier with the reference sine wave
- SPWM frequency equals the carrier frequency
- SPWM amplitude: ±10Vp
- Independent PWM signal generation
- IGBT gate driver output:
- 2 channels (HI and LO)
- Output amplitude: +15Vp
- Selectable between SPWM and standard PWM using a switch
10. Three-Phase PWM Inverter Control Module – TPAP.F1000
Origin: Vietnam
Technical Specifications
- Enclosure dimensions: 300 × 272 × 130 mm (W × L × H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 regarding power rating, current rating, leakage current, and dielectric strength
- Power supply: ±15VDC
Triangular Carrier Wave Generator
- Frequency ranges: 5kHz, 10kHz, 20kHz (switch selectable)
- Carrier amplitude: ±10Vp
Reference Sine Wave Generator
- Two output phases (A and B) with 120° phase displacement
- Frequency range: 0–100Hz
- Frequency control input: 0–10V
- Amplitude: ±10Vp
Signal Processing
- V/F ratio control for phases A and B
- Phase C sine-wave generation:
- Frequency: 0–100Hz
- Amplitude: ±10Vp
- Phase displacement: 120° relative to phases A and B
SPWM Generation and IGBT Gate Drive
- 3 HI outputs and 3 LO outputs
- Output frequency equal to the carrier frequency
- Output amplitude: +15Vp
11. Three-Phase Bridge Rectifier Training Module – TPAP.E3000
Technical Specifications
- Box dimensions: 300 x 272 x 130 mm (W x D x H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 standards for power/current ratings, leakage current, and dielectric strength
- Input voltage: Single-phase or three-phase 20 ~ 220V/50Hz
- Output voltage: 28 ~ 380VDC
- Rated current: 10A
- Equipped with output voltage filter capacitor
- Protection against voltage surges, overload, and short circuit
Main Components
- 01 Bakelite front panel
- 01 plastic enclosure
- 01 set of M4 connectors
- 01 three-phase bridge rectifier circuit
- 01 three-phase, 2-position switch
- 01 fuse
12. Three-Phase Power Bridge Module – TPAP.E3100
Technical Specifications
- Box dimensions: 300 x 272 x 130 mm (W x D x H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 standards for power/current ratings, leakage current, and dielectric strength
- Power supply: 220V/50Hz
- DC input voltage: 20 ~ 300VDC
- Inverter output voltage: 20 ~ 300Vp
- Rated output current: 10A
- Control circuit: Optical isolation and IGBT driver
- Control inputs: 06 digital inputs with 15Vp amplitude
- Test points: 06 outputs for 6 IGBT gate terminals
- IGBT power bridge: 40A/600V
- Overcurrent and short-circuit protection
Main Components
- 01 Bakelite front panel
- 01 plastic enclosure
- 01 set of M4 connectors
- 01 three-phase inverter bridge circuit
- 01 power supply circuit
- 02 fuses
- 01 illuminated power switch
- 01 transformer
13. Transformer Training Module (Isolation Transformer) – TPAE.L4500
Technical Specifications
- Box dimensions: 350 x 210 x 300 mm (D x W x H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 standards for power/current ratings, leakage current, and dielectric strength
- Input power supply: 3-phase, 380VAC/50-60Hz, star connection
- Output supply: 3-phase
- Output voltage per phase: 0~64VAC~95VAC~110VAC~127VAC~220VAC / 50-60Hz
- Transformer capacity: 6KVA
- Integrated phase indicator lamps
- Primary overcurrent protection by fuse
Main Components
- 01 set of M4 connectors
- 01 enclosure
- 01 module panel
- 01 transformer
- 03 fuses
- 03 phase indicator lamps
14. AC Motor Training Module – TPAE.F0300
Technical Specifications
- Dimensions: 293 x 180 x 279 mm (D x W x H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 standards for power/current ratings, leakage current, and dielectric strength
- Motor type: 3-phase AC motor
- Rated voltage:
- Y connection: 380VAC/50Hz
- Delta connection: 220VAC/50Hz
- Rated speed: 1420 rpm
- Housing material: Cast iron
- Power rating: 0.75 kW
Main Components
- 01 three-phase motor
- 01 set of M4 connectors
- 01 coupling
15. Fuse Training Module – TPAC.I0100
- Origin: Vietnam
- Module used for overload and short-circuit protection
Technical Specifications
- Box dimensions: 300 x 139 x 131 mm (D x W x H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 standards for power/current ratings, leakage current, and dielectric strength
- Number of branches: 04
- Rated current: 5A
Main Components
- 01 Bakelite front panel
- 01 plastic enclosure
- 04 fuses
16. Three-Phase Power Meter Training Module – TPAI.C4200
Technical Specifications
- Box dimensions: 300 x 272 x 131 mm (D x W x H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 standards for power/current ratings, leakage current, and dielectric strength
- Power supply: 3-phase AC
- Power measurement range: 0 ~ 10 kW
- Display type: Analog pointer
- Display angle: 90°
- Current transformer ratio: 20/5
Main Components
- 01 Bakelite front panel
- 01 plastic enclosure
- 01 set of M4 connectors
- 02 current transformers
- 01 analog three-phase power meter
17. AC Voltage Meter Training Module – TPAI.B0100
Technical Specifications
- Box dimensions: 300 x 139 x 131 mm (D x W x H)
- Standards:
- ISO 9001:2015 Quality Management System
- Compliant with TCVN 5699-1:2010 and IEC 60335-1:2010 standards for power/current ratings, leakage current, and dielectric strength
- Voltage measurement range: 0 ~ 500VAC
- Display type: Analog pointer
- Display angle: 90°
- Equipped with volt selector switch for measuring phase voltages
Main Components
- 01 Bakelite front panel
- 01 plastic enclosure
- 01 set of M4 connectors
- 01 volt selector switch
- 01 analog AC voltmeter 500V
18. Accessories Set
- Safety connection cables, Ø4 mm
- Rated current capacity: 19A
- Sufficient quantity of connectors for practical exercises
19. User Manuals
- Documentation includes:
- Equipment user manual
- Practical training manual
20. ETEK-Lab Digitalization, Simulation, and Practical Training Support Software
a. General Features
- Vietnamese interface, user-friendly and easy to operate
- Web-based platform accessible via Internet browser
- Allows anytime, anywhere access using personal accounts
- Supports login with individual usernames and passwords
- Supports role-based access control (teachers and students)
- Supports storage and management of lectures, learning materials, and practice documents
- Course contents, lectures, and practical exercises can be continuously updated by users
- Supports effective utilization of theoretical and practical training materials associated with training equipment
- Software data deployed on the supplier’s Cloud Server
- Software is copyrighted and certified by the Copyright Office
b. Lecture Development Support Functions
- Import lecture content from Word files
- Create lectures directly within the software
- Supports insertion of visual illustrations
- Supports multiple types of multiple-choice questions
- Allows creation of question banks for assessment and evaluation
- Lecture content management
c. AI-Integrated Teaching Support Technology
- The software integrates Artificial Intelligence (AI) technology to support teachers in developing training content, preparing lectures, and designing tests
- AI helps reduce lecture preparation time and supports rapid, scientific, and effective training content development
- Supports creation of lecture structures based on topics or course contents
- Automatically generates key lecture components: learning objectives, knowledge content, illustrative examples, and discussion questions
- Supports summarizing lengthy documents into key teaching points
- Supports converting technical documents into learner-friendly lecture content
- Supports editing, refining lectures, and adding illustrative examples or real-life scenarios
- Generates illustrations and visual diagrams appropriate to lesson content
- Automatically generates assessment questions from lecture content such as multiple-choice, true/false, matching, and fill-in-the-blank questions
d. Simulation
- Software for teaching and simulating the basic principles of Power Electronics using animations and interactive simulations
- Includes detailed theoretical content covering both basic and advanced principles
- Theory and simulation of electronic components and power electronic devices: insulation, semiconductors, diodes, transistors, and power electronic devices
- Simulation of triggering and switching methods: Thyristor turn-on/turn-off methods and gate triggering methods
- Simulation of gate triggering circuits: common triggering circuits, resistance triggering circuits, half-wave and full-wave resistance triggering circuits, UJT oscillator, synchronized UJT triggering, ramp triggering circuits
- Simulation of phase-controlled rectifiers
- Simulation of chopper circuits: DC-DC choppers, buck converters, boost converters, AC voltage choppers, and applications
- Simulation of direct converters: triggering diagrams, single-phase direct converters, and applications
- Simulation of AC voltage controllers